Reliability of B-mode ultrasonography for abdominal muscles in asymptomatic and patients with acute low back pain

  • Asghar Norasteh, M.S.P.T.

      Affiliations

    • Guilan University, Rasht, Iran
    • Corresponding Author InformationCorresponding author. No. 625 Shaghayegh Ave., Park St. Hamila Highway, Poonak, Tehran, Iran. Tel. +98214431527; fax: +98212220946.
  • ,
  • Esmaeil Ebrahimi, Ph.D., P.T.

      Affiliations

    • Faculty of Rehabilitation Sciences of Iran Medical Sciences University, Tehran, Iran
  • ,
  • Mahyar Salavati, Ph.D., P.T.

      Affiliations

    • USWR, Tehran, Iran
  • ,
  • Javad Rafiei, M.D.

      Affiliations

    • Department of Radiology,IUMS, Tehran, Iran
  • ,
  • Enayatolla Abbasnejad, M.D.

      Affiliations

    • Department of Neurosurgery, IUMS, Tehran, Iran

Received 13 October 2005; received in revised form 27 October 2005; accepted 1 November 2005.

Summary 

The purpose of this methological study was to develop a reliable method for measuring transversus abdominis, rectus abdominis, external oblique and internal oblique muscles in asymptomatic human subjects and patients with acute low back pain (ALBP). This was a single operator reliability design study using ultrasound imaging to measure muscle thickness in 27 subjects on three separate occasions. Intra-class correlation coefficients (ICC) and standard error of measurement (SEM) were used to analyze muscle thickness. The mean, SD, ICC and SEM for external oblique, internal oblique, transversus abdominis and rectus abdominis muscles in asymptomatic subjects were (5.38, 1.64, 0.96, 0.33), (9.35, 3.42, 0.97, 0.073), (4.36, 1.93, 0.81, 0.45), (10.8, 2.18, 0.85, 0.84), respectively. The mean, SD, ICC, SEM for external oblique, internal oblique and transversus abdominis muscles in patients with ALBP were (5.58, 0.97, 0.87, 0.35), (9.72, 1.92, 0.87, 0.31), (4.36, 1, 0.91, 0.3), respectively. Earlier study on ultrasonographic measurement for neck multifidus muscles has suggested that the reliability of muscle thickness is higher in asymptomatic subjects compared with those in the symptomatic subjects. However, the present study showed high reliability for both symptomatic and asymptomatic subjects. This difference may be related to non-atrophic changes in abdominal muscles in acute low back patients. The results of this study indicate that the measurement of abdominal muscle thickness with B-mode ultrasonography can be performed reliably even in patients with ALBP.

Keywords: B-mode ultrasonography, Reliability, Abdominal muscles

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1360-8592(05)00133-6

doi:10.1016/j.jbmt.2005.11.002

Journal of Bodywork and Movement Therapies
Volume 11, Issue 1 , Pages 17-20, January 2007